The VCL-2424 is a compact, industrial grade DIN Rail mounted GPS / GNSS, ITU-T G.811 Primary Reference Master Clock (PRC), PTP IEEE-1588v2 Grandmaster and NTP Time Server synchronization solution that is designed to be installed in harsh environments to provide highly precise time and phase synchronized frequency and time of day references.
User applications include industrial application, electric sub-stations, power distribution infrastructure, solar farms, wind-farms, railways and metro signaling infrastructure, airports and air-traffic control facilities, 2G, 3G, 4G and LTE mobile cell towers, off-shore oil and gas rigs and naval vessels that are required to operate in complete isolation due to the very nature of their application, geographical location or due to security reasons.
The VCL-2424 is equipped with a highly accurate, low-noise OCXO to provide a high stability, ITU-T G.812, Type II, III compliant holdover clock with better than 12μs accuracy over a 24-hour (5 milliseconds per year) period in the event of unavailability of the GNSS (GPS/GLONASS) signal, or GNSS (GPS/GLONASS) antenna failure, or a temporary loss of reception occurring due to stormy weather conditions or solar flares or without any external reference.
VCL-2424 establishes a highly accurate phase-synchronized frequency and time base by synchronizing to the GNSS (GPS/GLONASS) satellites' atomic clocks to distribute synchronized time over packet based networks including Ethernet, Carrier Ethernet, IP and IP/MPLS Networks.
The VCL-2424 provides a wide range of GNSS (GPS/GLONASS) referenced frequency and time sources (outputs) that include 2.048MHz, 10MHz, 1PPS as well as an NMEA, 1588v2 PTP and an NTPv4 time reference. Features such as maintaining a distinctly separate IP address for system management and control, password based access, SSH as well as MD5 authentication ensures operational reliability and security. Additional features include remote login and remote firmware upgrade (file transfer) capabilities. VCL-2424 includes complete SNMP monitoring as well as support for enterprise directory services for user authentication, internal and external logging and monitoring of alarm and error messages through Syslog ensures a high level of system manageability. Other features includes support concurrent IPv4/IPv6 support for future network upgradation
Application Diagram:
Performance:
Features and Highlights
Monitoring and Management:
The configuration of the system can be managed by Graphical User Management Interface. Alternatively, a text based and menu driven setup utility can be started via Telnet or SSH. An optional Graphical User Network Management Interface (NMS) allows multiple systems to be monitored and configured from single or multiple management locations.
Synchronization Inputs:
Frequency Outputs:
PTP IEEE 1588-2008 V2 Grandmaster:
PTP Outputs:
NTP Output:
GPS/GNSS Receiver Specifications:
Network Time Protocol:
Frequency Outputs:
PTP IEEE 1588-2008 V2 Grandmaster:
PTP Profiles:
Antenna Specifications: