Failsafe - The equipment itself never becomes a point of failure. It automatically reverts to and reconnects to the primary link even in power down condition.
The VCL-SafeComm, 16 E1 Links (48 E1 Ports), 1+1 Automatic Protection / AB Fallback Switching (APS) Equipment may be used to protect upto 16 E1 Links (48 E1 Ports), point-to-point links and provide an alternate communication route to each E1 Link between any two E1 points. In the event of the failure of the primary (Main) E1 communication route, the VCL-SafeComm, 16 E1 Links (1+1 Automatic Protection / AB Fallback Switching Equipment) automatically switches the E1 traffic to a secondary (standby) E1 route. The VCL-SafeComm, 16 E1, 1+1 Automatic Protection / AB Fallback Switching equipment is available in a 2U high chassis which may be mounted in any DIN standard,19-Inch rack.
This product allows the user to design 1+1 (protected) redundant E1 routes on similar (fiber-fiber), or complementing (fiber-radio) transmission mediums.
The criterion for switching between the primary (main) and the secondary (protected/standby) routes is user programmable.
Criterion for switching between the primary (main) and the secondary (protected / standby) routes may be Loss-Of-Signal on E1 links, or AIS (All-Ones AIS alarm) condition. The criterion for switching time and recovery time between the primary (main) and the secondary (protected / standby) routes is user programmable.
Data transported on the E1 Links is transparent and protocol independent.
There are three modes in which the VCL-SafeComm E1, 1+1 Automatic Protection / AB Fallback Switch can be configured to operate in:
AUTOMATIC SWITCHING MODE:
EXTERNAL TRIGGER SWITCHING MODE:
MANUAL SWITCHING MODE:
Product Application Note: 8/16 E1/T1 Links (24/48 E1/T1 Ports), 1+1 Automatic Protection / AB Fallback Switching Equipment: This equipment is to be used when the customer wants to use two different E1/T1 links of the network to establish a 1+1 redundant path to ensure continued E1/T1 service bewteen two points even if one of the network E1/T1 link fails. Example - the customer may want to use E1/T1 Optical Fiber and an E1/T1 Radio link and to provide an ACTIVE and a STANDBY link between a BSC and a BTS so that when the E1/T1 Optical Fiber (ACTIVE) link goes down the STANBY / REDUNDANT E1/T1 Radio link automatically gets connected to provide continued connectivity and service between the BSC and the BTS.
Product Application Note: The E1/T1 Fail-Over Switch should be used when the customer is using a single E1/T1 link to provide protection equipment to the customers premises by using one E1/T1 ACTIVE and one E1/T1 STANDBY equipment (such as a ROUTER or a PBX). The E1/T1 Failover Switch shall automatically switch the E1/T1 that is being received from the telephone company between the ACTIVE E1/T1 equipment and the STANDBY E1/T1 equipment. Should the ACTIVE E1/T1 equipment go bad or be removed from service, the E1/T1 link from the telephone company automatically gets switched to the STANDBY E1/T1 equipment without any customer or user intervention.
System Access, Control and Management Options:
Providing 1+1 alternate paths between any two Transmission mediums (active+standby). e.g:
Example: The user may deploy the VCL-SafeComm, 16 E1, 1+1 Automatic Protection / AB Fallback Switching Equipment to provide an alternate communication route between an optical fiber link and a radio link between any two points. In the event of the failure of the primary (optical fiber) link the E1 is automatically switched to the alternate route over the E1 radio, thus ensuring maximum uptime on all such 1+1 protected E1 Links.
Once the primary (optical fiber) E1 Link on the optical fiber is restored, the VCL-SafeComm, 16 E1, 1+1 Automatic Protection / AB Fallback Switching Equipment automatically restores the communication to the primary (optical fiber) E1 Link. The switching and restoration criterion is user programmable.
Features
Point-to-Point Application: May be used in a point-to-point configuration to provide 1+1 protected / Alternate Routing Path between any two point, using diverse (or similar) E1 transmission mediums.
Valiant Communications is an ISO 9001:2015, ISO 10001:2018, ISO 14001:2015, ISO 27001:2013 and ISO 45001:2018 certified equipment manufacturer.
Home
About Us
Solutions
Applications
Data Sheets
Press
Project & Services
Reference Customers
Contact Us
VCL IP/MPLS Routers
Teleprotection over E1, C37.94, MPLS-TP, MPLS / IP, IEC-61850 GOOSE
IEEE C37.94 Solutions
VCL-PMU-30, Phasor Measurement Unit (PMU)
VCL-PDC, Phasor Data Concentrator (PDC)
Cyber Security Solutions
Router with Enhanced Security
Industrial Switches
GPS / GNSS, Primary Reference Clocks (G.811)
GPS / GNSS NTP Time Server
PTP IEEE-1588v2 Grandmaster, PTP Slave, PTP Transparent Clock
NTP to IRIG-B, PTP to IRIG-B
GPS to IRIG-B, GPS to 1PPS Servers
Time Distribution, IRIG-B, 1PPS, RS-232 / RS-485
SDH with MPLS-TP & SONET Multiplexers
E1 PDH & Digital Cross Connect
Optical Multiplexers
IP over TDM / Ethernet over TDM
TDM over IP / Ethernet / Packet / MPLS
E1 / T1, 1+1 Automatic Protection / Failover
1+1 Ethernet Failover / AB Fallback Switch
Groomer (Hi-Z Non-Intrusive Monitoring) - E1, T1 and STM-1
E1 and T1 Echo Cancellers & VQE
Serial to Ethernet and MODBUS Converters
Patch Panels, AC DC Converters, Passive Products